The only place air should be able to leave the supply duct system and the furnace or air handling unit is at the supply registers. Cabinet seams, holes, and junctions should be sealed to prevent air leakage. Air leakage problems can be worst at the HVAC furnace or air handler cabinet, where air pressures are highest. If the ducts are leaky, they can be a source of energy loss through loss of heated or cooled air, poor HVAC performance through loss of air pressure in the ducts, and comfort problems. Many homes are equipped with central forced air systems that rely on ducts to transport heated or cooled air from a furnace or heat pump to the rest of the home. See the Compliance Tab for related codes and standards, and criteria to meet national programs such as ENERGY STAR, DOE’s Zero Energy Ready Home program, and EPA’s Indoor airPLUS.

The space in between two air locks code#

Verify that the duct system meets code or program airtightness requirements. Use a duct blower tester to test the airtightness of the air handler/furnace cabinet and ducts.If the insulation has been compromised, repair it with approved spray glue and additional insulation. Check the insulation inside the air handler where the conduit enters.Use a sealing putty to seal the inside of the high-voltage wire conduit termination point in the air handler after the wiring has been installed.Seal all fixed seams in the cabinets and all seams between the cabinet and the supply or return plenums with mastic or mastic and fiberglass mesh fabric.Seal all unused conduit knockouts with UL-listed tape or mastic.Use UL-approved gaskets to seal cabinet doors and access panels.Use putty around all conduit and wiring holes.

The space in between two air locks plus#

  • Use mastic, mastic plus embedded fiberglass mesh fabric, or UL 181A or B tape to seal all cabinet seams and junctures between the air handler or furnace cabinet and the evaporator coil cabinet, the supply plenum and the return plenum.
  • the space in between two air locks

    Select an air handler with a manufacturer’s designation showing that air leakage is ≤2% of the design air flow rate.Too sudden a change of pressure may cause decompression sickness.Seal seams and holes in the air handler or furnace cabinet of central forced air HVAC systems to prevent the loss of conditioned air. Great care must be exercised in passing workmen through an air lock, so that the change of atmospheric pressure takes place gradually. The reverse of this procedure takes place on leaving the working chamber. After the outer door is closed, compressed air is admitted to raise pressure in the air lock to the level of the pressure in the working chamber, and the inner door can be opened. When the outer door of the air lock is opened, men or material may be admitted into the compartment. It is also used at the head of tunnel excavations underwater. By its means access can be gained to the working chamber without loss of pressure. A more common example is the air lock between the outer atmosphere and the working chamber of a caisson.

    the space in between two air locks